About PLCCalcs.com
Built for Commissioning & Controls Engineers
PLCCalcs.com was created to give PLC programmers, instrumentation technicians, and control panel designers fast, distraction-free calculators that work reliably on a laptop or phone on the plant floor—with zero signups, zero paywalls, and instant PWA offline-friendly installation.
Engineering Standards & Numerical Rigor
- Exact 16/32-Bit Two's-Complement Bitwise Logic: Uses native
BigIntarithmetic so bit 31 in 32-bitDINTMasked Move (MVM) andTOD/FRDoperations never suffers JavaScript signed-shift corruption. - IEC 60751 & NIST ITS-90 Sensor Polynomials: Implements full fourth-order Callendar–Van Dusen RTD equations (with Newton–Raphson inversion) and official NIST ITS-90 thermocouple EMF polynomials with live Cold Junction Compensation.
- Open Protocol & Thermal Standards: Follows Modbus over Serial Line V1.02 (
0xA001Little-Endian CRC-16 andt3.5inter-frame timing), TIA/EIA-485 Unit Load rules, NAMUR NE43 4–20mA fault thresholds, and IEC 60890 enclosure thermal transfer coefficients.
Feedback & Contact
Spotted an edge case or want to request a new PLC / SCADA calculator? Reach us anytime at support@plccalcs.com.
Complete PLC & Industrial Automation Calculator Suite
Bitwise & Data Formats
Simulate 16-bit INT and 32-bit DINT Masked Move instructions bit-by-bit with clickable mask gates and Structured Text output.
Decode or encode two 16-bit Holding Registers across all 4 endian byte orders (ABCD, CDAB, BADC, DCBA) for 32-bit REAL floats.
Convert between 16/32-bit Binary-Coded Decimal (BCD) thumbwheel words and integer values with invalid A–F nibble fault detection.
Analog I/O & Sensors
Convert raw ADC counts (4000–20000, 6241–31206, 0–27648) and 4–20 mA signals into engineering units with 5-point calibration tables.
Bidirectional Callendar–Van Dusen (°C/°F ↔ Ohms) calculator for PT100 and PT1000 RTDs with Class AA, A, and B tolerance bands.
Convert thermocouple millivolt (mV) readings to process temperature and back with live Cold Junction Compensation (CJC).
Estimate cabinet temperature rise, conductive heat transfer, required cooling fan airflow (CFM), and AC capacity (BTU/hr) for enclosures.
Fieldbus, Motion & Control
Compute polynomial 0xA001 CRC-16 checksums in Little-Endian Lo-Byte / Hi-Byte wire order and validate captured RS-485 frames.
Calculate maximum RS-485 trunk length, Modbus RTU 3.5-character silent interval (t3.5), frame duration, and max polling rate.
Compute synchronous speed, motor slip %, output shaft RPM after gearbox reduction, and target VFD command frequency in Hz.
Verify PLC High-Speed Counter (HSC) kHz input limits from encoder PPR, 1x/2x/4x quadrature decoding, shaft RPM, and linear travel.
Convert Independent (Kp, Ki, Kd) vs. ISA Dependent (Kc, Ti, Td) PID gains and compute FOPDT / Ultimate Gain starting parameters.